Power Transformer ABB 50KVA 11.00/0.415KV
- SKU:
 - ABB 50KVA 11.00/0.415KV
 - UPC:
 - MPN:
 - ABB 50KVA 11.00/0.415KV
 - Weight:
 - 3,123.00 KGS
 - Shipping:
 - Calculated at Checkout
 
₦0.00
- Pick up from the Chiviselectricals Store
 
To pick up today
Free
- Courier delivery
 
Our courier will deliver to the specified address
2-3 Days
Free
- Warranty 1 year
 
- Free 30-Day returns
 
Payment Methods:
Description
Power Transformer ABB 50KVA 11.00/0.415KV?
Chivis electrical Concepts is the supplier and distributor of?ABB brand?of Power Transformers?in Nigeria. Our Power Transformer ABB 50KVA 11.00/0.415KV?is designed to grant?reliability, durability, and efficiency required in utility, industrial, and commercial applications. This distribution transformers are designed and manufactured to the highest quality standards to ensure enduring reliability, a characteristic necessary to foster peace of mind amongst customers and consumers.?
Technical Specifications of?Power Transformer ABB 50KVA 11.00/0.415KV?
- Product Name:?Liquid-Filled Groundmount Transformer; 3PH, 1500 kVA, HV 11000D , LV 415yn
 - Rated Power 50[kVA]?
 - Insulation Liquid: Mineral Oil
 - High Voltage: 11000[V]?
 - High Voltage tappings (DETC):?+2 -2 2.5%
 - Low Voltage at no Load: 415[V]?
 - Number of phases 3
 - Vector Group: Dyn11
 - Ambient temperature max./monthly/annual average: ?C 40 / / 20
 - Max. average temperature rise (Oil/Winding):?60 / 65[C/C]?
 - Location Indoor/Outdoor
 - Rate Voltage: 11-0,415KV
 - Frequency:?50[Hz]?
 - Impedance: 6(+-10%)[%]?
 - No Load Losses: 2800(+15%)[W]?
 - Load Losses at 75 ?C:?20000(+15%)[W]?
 - Standards: IEC 60076
 - Total Weight: 3123[kg]?
 - Cooling: ONAN
 
Frequently Asked Questions?
1. What is the power transformer used for?
Power transformers are frequently used to step up and step down voltages at the electrical power generating station and distribution stations.
2. Why is the transformer used in kVA?
Transformers are used and rated in kVA, to account for power losses. The total heat losses in a transformer depends on volt-ampere (VA) only and not on the power factor of the load. That is why the transformer rating is given in kVA and not in kW.?
3. What is the difference between a power transformer and an instrument transformer?
A power transformer is primarily used in power transmission and distribution to either step up or step down a voltage level. While an instrument transformer is used in a circuit for the measurement of voltage or current.
?Related Articles
How do power transformers work?
10 Benefits of using a Transformer
Power transformer maintenance
Contact Us?for product availability?