range of product |
EasyPact
|
|
---|---|---|
product or component type |
Circuit breaker
|
|
device short name |
Easypact EZC100F
|
|
circuit breaker name |
Easypact EZC100F
|
|
device application |
Distribution
|
|
poles description |
3P
|
|
protected poles description |
3t
|
|
network type |
DC
AC |
|
network frequency |
50/60 Hz
|
|
[In] rated current |
100?A at 40??C
|
|
[Ui] rated insulation voltage |
690?V AC 50/60 Hz conforming to IEC 60947-2
|
|
[Uimp] rated impulse withstand voltage |
6?kV conforming to IEC 60947-2
|
|
[Ue] rated operational voltage |
550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2 |
|
breaking capacity code |
F
|
|
breaking capacity |
25?kA Icu at 110?130 V AC 50/60 Hz conforming to IEC 60947-2
25?kA Icu at 220?240 V AC 50/60 Hz conforming to IEC 60947-2 5?kA Icu at 125 V DC 1P conforming to IEC 60947-2 5?kA Icu at 250 V DC 2P conforming to IEC 60947-2 5?kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 10?kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 10?kA Icu at 400?415 V AC 50/60 Hz conforming to IEC 60947-2 7.5?kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
|
[Ics] rated service breaking capacity |
12.5?kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
12.5?kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5?kA at 125 V DC conforming to IEC 60947-2 2.5?kA at 250 V DC conforming to IEC 60947-2 2.5?kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 5?kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5?kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 3.75?kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
|
suitability for isolation |
Yes conforming to IEC 60947-2
|
|
utilisation category |
Category A
|
|
trip unit name |
TM-D
|
|
trip unit technology |
Thermal-magnetic
|
|
trip unit rating |
50?A at 50??C
|
|
protection type |
Overload protection
Short-circuit protection |
|
pollution degree |
3 conforming to IEC 60664-1
3 conforming to IEC 947-1 |
control type |
Toggle
|
|
---|---|---|
mounting mode |
Fixed
|
|
mounting support |
Backplate
|
|
upside connection |
Front
|
|
downside connection |
Front
|
|
mechanical durability |
8500?cycles
|
|
electrical durability |
Category A: 1500?cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
|
|
connection pitch |
25?mm
|
|
local signalling |
Positive contact indication
|
|
neutral protection setting |
Without protection
|
|
earth-leakage protection |
Without
|
|
height |
130?mm
|
|
width |
75?mm
|
|
depth |
60?mm
|