ABB Power Transformer 50KVA 33/0.415KV

SKU:
ABB PT50KVA33
MPN:
ABB PT50KVA33
Weight:
1,400.00 KGS
Shipping:
Calculated at Checkout
SKU: NTU7092

2,117,750.00

19 People watching this product now!
  • Pick up from the Chiviselectricals Store

To pick up today

Free

  • Courier delivery

Our courier will deliver to the specified address

2-3 Days

Free

  • Warranty 1 year
  • Free 30-Day returns

Payment Methods:

Description

Description

ABB Power Transformer 50KVA 33/0.415KV

Chivis electrical Concepts is the supplier and distributor of?ABB brand?of power transformer?in Nigeria. Our ABB?Power Transformer 50KVA 33.0/415KV is part of a complete range of copper power transformers designed to grant the reliability, durability, and efficiency required in utility, industrial, and commercial applications.

The ABB Power Transformer 50KVA 33/0.415KV power transformers are designed and manufactured to the highest quality standards to ensure enduring reliability, a characteristic necessary to foster peace of mind amongst customers and consumers.

Technical Specifications of?ABB Power Transformer 50KVA 33/0.415KV

  • Product Name:?Liquid-Filled Ground mount Transformer; 3PH, 500 kVA, HV 11000D , LV 415yn
  • Rated Power 50[kVA]?
  • Insulation Liquid: Mineral Oil
  • High Voltage: 33 000[V]?
  • High Voltage tappings (DETC):?+2 -2 2.5%
  • Low Voltage at no Load: 415[V]?
  • Number of phases 3
  • Vector Group: Dyn11
  • Ambient temperature max./monthly/annual average: ?C 40 / / 20
  • Max. average temperature rise (Oil/Winding):?60 / 65[C/C]?
  • Location Indoor/Outdoor
  • Rate Voltage: 33-0,415KV
  • Frequency:?50[Hz]?
  • Impedance:?4(+-10%)[%]?
  • No Load Losses: 1350(+15%)[W]?
  • Load Losses at 75 ?C: 7200(+15%)[W]?
  • Standards: IEC 60076
  • Total Weight: 1400[kg]?
  • Cooling: ONAN

Frequently Asked Questions

1. Can transformers be operated at voltages other than the prescribed voltages?

Transformers can sometimes be used at voltages that are lower than the rated voltage. However the voltage rating of a transformer should NEVER be exceeded unless taps are provided for this reason. Note, when operating below the rated voltage the KVA capacity is reduced correspondingly.

2. What is meant by impedance in transformers?

Impedance is the transformer’s ability to restrict current and is expressed in percentage.

3. What does a transformer rating mean?

The rating of a transformer is the maximum power which can be drawn from it without the temperature rise in the winding to go over what is considered safe for the specific kind of insulation used.